Referans Bilgileri
Some considerations on seismic design and controls of sloshing in floating-roofed oil tanks
F. Sakai, R. Inoue
Proceedings of the 14th World Conference on Earthquake Engineering
2008/10/12
During 2003 Tokachi-Oki earthquake (M=8.0) in Japan, many oil storage tanks in Tomakomai were damaged by sloshing due to long-period strong ground motion with high level from 4 to 8 seconds. In this paper, to establish countermeasures against sloshing for floating-roofed oil tanks, the authors investigate sloshing behaviors in consideration of the existence of actual floating-roof, and propose some countermeasures such as an earthquake-resistant structure, an isolation system and a vibration control method for floating-roof sloshing.
Anahtar Kelimeler: seismic design, vibration control, sloshing, floating-roof, oil tank, long-period motion
Beijing, China
Bildiriler Kitabı Bölümü
Dosyalar
Makale (450.52KB) |
İlgili Kayıtlar
Konu Başlıkları
No | Başlık |
---|---|
1. | Bilimsel Çalışmalar » Doğal Afet Risk Değerlendirmesi » Çalkalanma |